Product data sheet
Nominal diameter of Laval nozzle
2 mm
Grid size
22 mm
Silencer design
Normally closed
Installation location
Optional
Ejector features
High vacuum degree
Filter level
≤40 µm
Manual control device
Button type
Integrated functionality
Electronic control injection pulse valve
throttle
Electric control switch valve
filter
One-way valve
vacuum switch
Measured variables
Relative pressure
measuring principle
Piezoresistive type
Switching element function
Normally open contact
Switch function
Threshold comparator
Symbol
00991306
Valve function
close
Reverse polarity protection
Suitable for all electrical connections
Display type
LED
Hysteresis setting range
-0.05 Mpa ... - 0.005 Mpa
Set range delay
-0.5 bar ... - 0.05 bar
Set range delay
-7.25 psi ... - 0.725 psi
set an option
Potentiometer
Switch status indication
optics
Threshold setting range
-0.09 Mpa ... 0 Mpa
Threshold setting range
-0.9 bar ... 0 bar
Threshold setting range
-13.05 psi ... 0 psi
working pressure
0.2 Mpa ... 0.8 Mpa
working pressure
2 bar ... 8 bar
working pressure
29 psi ... 116 psi
Maximum vacuum degree
85 %
Rated working pressure
0.6 Mpa
Nominal working pressure
6 bar
Rated working pressure
87 psi
Maximum overload pressure
5 bar
Air source time with jet pulse and at rated working pressure
0.15 s
Working voltage range DC
21.6 V ... 26.4 V
Continuous power on rate
100%
Switch output
PNP
authentication
RCM trademark
C UL us - Certified (OL)
CE certification (see declaration of conformity)
Compliant with EU Electromagnetic Compatibility Directive
CE marking (see declaration of conformity)
Compliant with UK EMC Directive
Working medium
Compressed air, in accordance with ISO 8573-1:2010 [7:4:4]
Description of Work and Pilot Media
Not working with lubricating media
Corrosion resistance grade CRC
2- Moderate corrosion resistance
Paint Wetting Defect Substance (PWIS) Compliance
VDMA24364-B1/B2-L
Medium temperature
0 °C ... 60 °C
Protection level
IP65
ambient temperature
0 °C ... 50 °C
Product weight
360 g
Pressure measurement range
0 Mpa ... 0.1 Mpa
Pressure measurement range
0 bar ... 1 bar
Pressure measurement range
0 psi ... 14.5 psi
Electrical interface
4 needles
M8x1
Plug
Installation method
or
With through-hole
Installation through internal threads
Air interface, air port 1
G1/4
Air interface, air port 3
Integrated silencer
Vacuum interface
G3/8
Material Description
RoHS compliance
Sealing material
NBR
Material of intake nozzle
Nickel plated brass
Filter material
PA
Filter housing material
PC
Shell material
Refined aluminum alloy
Muffler material
PE
POM
Piston material
POM
Emitter nozzle material
Nickel plated brass