Product data sheet
Popular Downloads
Data Sheet, Technical Information:Instructions and Manuals:CAD Dimensional Drawing:
Data Sheet, Technical Information:
Instructions and Manuals:
CAD Dimensional Drawing:
Dimensions
Product Net Width:22.5 mmProduct Net Height:85.6 mmProduct Net Depth / Length:103.7 mmProduct Net Weight:0.127 kg
Product Net Width:
22.5 mm
Product Net Height:
85.6 mm
Product Net Depth / Length:
103.7 mm
Product Net Weight:
0.127 kg
Technical
Function:Phase failure detectionPhase sequence monitoringMeasuring Range:(L-L) 200 ... 500 V ACTime Range:500 ms start-up delayRated Control Supply Voltage (Us):(L-L) 200 ... 500 V ACRated Frequency (f):Supply Circuit 50/60 HzOutput:2 c/o (SPDT) contactsTerminal Type:Screw TerminalsRated Operational Current AC-12 (Ie):(230 V) 4 ARated Operational Current AC-15 (Ie):(230 V) 3 ARated Operational Current DC-12 (Ie):(24 V) 4 ARated Operational Current DC-13 (Ie):(24 V) 2 AMinimum Switching Capacity:24 V10 mARated Impulse Withstand Voltage (Uimp):Input Circuit 6 kVOutput Circuit 4 kVRated Insulation Voltage (Ui):Input Circuit / Output Circuit 600 VOutput Circuit 1 / Output Circuit 2 300 VDegree of Protection:Housing IP50Terminals IP20Overvoltage Category:IIIPollution Degree:3Short-Circuit Protective Devices:Output Circuit NC - F Type Fuses 6 AOutput Circuit NO - F Type Fuses 10 AElectrical Durability:AC-12 100000 cycleMechanical Durability:30000000 cycleConnecting Capacity:Flexible with Ferrule 1x 0.5 ... 2.5 mm²Flexible with Ferrule 2x 0.5 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²Flexible 1x 0.5 ... 2.5 mm²Flexible 2x 0.5 ... 1.5 mm²Rigid 1x 0.5 ... 4 mm²Rigid 2x 0.5 ... 2.5 mm²Tightening Torque:0.6 ... 0.8 N·mWire Stripping Length:8 mmRecommended Screw Driver:0.8 x 44.5Pozidriv 1Mounting Position:1 ... 6Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715Standards:CAN/CSA C22.2 No.14IEC/EN 63000IEC/EN 60255-27IEC/EN 61000-6-2IEC/EN 61000-6-3UL 508
Function:
Phase failure detection
Phase sequence monitoring
Measuring Range:
(L-L) 200 ... 500 V AC
Time Range:
500 ms start-up delay
Rated Control Supply Voltage (Us):
(L-L) 200 ... 500 V AC
Rated Frequency (f):
Supply Circuit 50/60 Hz
Output:
2 c/o (SPDT) contacts
Terminal Type:
Screw Terminals
Rated Operational Current AC-12 (Ie):
(230 V) 4 A
Rated Operational Current AC-15 (Ie):
(230 V) 3 A
Rated Operational Current DC-12 (Ie):
(24 V) 4 A
Rated Operational Current DC-13 (Ie):
(24 V) 2 A
Minimum Switching Capacity:
24 V
10 mA
Rated Impulse Withstand Voltage (Uimp):
Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui):
Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of Protection:
Housing IP50
Terminals IP20
Overvoltage Category:
III
Pollution Degree:
3
Short-Circuit Protective Devices:
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical Durability:
AC-12 100000 cycle
Mechanical Durability:
30000000 cycle
Connecting Capacity:
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque:
0.6 ... 0.8 N·m
Wire Stripping Length:
8 mm
Recommended Screw Driver:
0.8 x 4
4.5
Pozidriv 1
Mounting Position:
1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Standards:
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Tags:
HDL24081405