Product data sheet
TECHNICAL DATA
Inputs
Accuracy 0,2% f.s. ±1digit.
Sampling time 120msec.
TC - Thermocouple
J 0...1000°C / 32...1832°F
K 0...1300°C / 32...2372°F
R 0...1750°C / 32...3182°F
S 0...1750°C / 32...3182°F
T -200...400°C / -328...752°F
B 44...1800°C / 111...3272°F
E -100...750°C / -148...1382°F
N 0...1300°C / 32...2372°F
L-GOST 0...600°C / 32...1112°F
U -200...400°C / -328...752°F
G 0...2300°C / 32...4172°F
D 0...2300°C / 32...4172°F
C 0...2300°C / 32...4172°F
(NI-Ni18Mo) 0...1100°C / 32...2012°F
custom -1999...9999
RTD 2/3 wires
PT100 -200...850°C / -328...1562°F
JPT100 -200...600°C / -328...1112°F
PTC
990Ω, 25°C -55...120°C / -67...248°F
NTC
1KΩ, 25°C -10...70°C / 14...158°F
FACEPLATE DESCRIPTION
DC - Linear
With scale settable from:
-1999...9999
0...60mV / 12...60mV
0...10V / 2...10V
0...5V / 1...5V
0...1V / 0,2...1V
0...20mA / 4...20mA
Input impedance:
Ri > 1MΩ for 60mV,1V
Ri > 10KΩ for 5V, 10V
Ri = 50Ω for 20mA
32-segment custom linearization can be
inserted.
Auxiliary input
(alternative to output out 3)
Input for current transformer
50mAac, 50/60Hz, Ri=10Ω
Digital input
Ri = 4,7KΩ (24V, 5mA) insulation 1500V
or no-voltage contact.
Function configurable for man/auto
selection, local/remote (setpoint from
serial line, setpoint1/setpoint2; Set/reset
outputs, start/stop functions from tuning,
software on/off, reset alarms memory,
hold.
Outputs
4 configurable outputs:
• OUT1-OUT4: relay only
• OUT2: relay, logic, triac, digital insulated
• OUT3: relay, logic, digital insulated,
continuous or analog retransmission as
alternative to aux. input
Freely assignable to control functions and
single alarms in “OR” or “AND”.
Can be slaved to front panel key or aux.
digital input.
Relay
(indicated in code with R)
With contacts: 5A at 250Vac/30Vdc,
cosj=1
Logic
(indicated in code with D)
24Vdc ±10% (10V min at 20mA)
Digital insulated (indicated in code with M)
optoinsulated MOS output 1500Vrms
equivalent to NO contact
Vmax 40Vac/Vdc Imax 100mA
Load ON max 0,8Ω
Triac
(indicated in code with T)
20...240Vac ± 10%, 50/60Hz, 1A max.
I
2
t = 128A2
sec.
Leakage current 1,5mA max at 200Vac.
Continuous
(indicated in code with C)
0...10V Rload ≥ 250KΩ
0/4...20mA Rload ≤ 500Ω
for heating/cooling control output only.
Analog retransmission
(indicated in code with W)
0...10V Rload ≥ 250KΩ
0/4...20mA Rload ≤ 500Ω max resolution
12 bit, useful for retransmission of variable.
Serial line
Isolated 2/4 wires, RS422/485 interface
(1200, 2400, 4800, 9600, 19200 baud)
Prot.: GEFRAN CENCAL or MODBUS
Power supply
Standard: 100...240Vac ± 10%
On request: 11...27Vac/dc ± 10%
50/60Hz, max. 10VA
Protection by internal fuse not serviceable
by user
Transmitter Power supply
24V ±10% non-stabilized, 30mA
15V for transmitter, 30mA
Short-circuit protection
Ambient Condition
Working temperature range: 0...50°C
Storage temperature range: -20...70°C
Humidity: 20...85%Ur non condensing
Control
On/Off, P, PD, PID for heating and cooling, with parameters settable from keys.
Cooling setpoint relative to heating setpoint.
• Manual reset -999...999 digit
• Power reset -100,0...100,0%
• Cycle time 0...200sec
• Softstart 0,0...500,0 min
For each action:
• Proportional band 0,0...999,9% f.s.
• Integral time 0,0...99,99 min
• Derivative time 0,0...99,99 min
• Max power limit 0,0...100,0%
Alarms
• 3 alarms settable as absolute, deviation,
symmetrical deviation to setpoint with
direct or reverse function.
• Alarm point can be set anywhere on
selected scale
• Alarms can be masked with exclusion at
power-on, with memory, with delayed trip
• LBA alarm for setting control
• Hysteresis settable for each alarm
• Alarm assigned to current input with different operating modes.
Weight
160g in complete version