Product data sheet
General data
Standards | EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
Coding level according to EN ISO 14119 | Low |
Working principle | electromechanical |
Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Gross weight | 100 g |
General data - Features
Increased latching force | Yes |
Suitable for elevators | Yes |
Number of safety contacts | 1 |
Number of cable glands | 3 |
Safety classification |
Standards | EN ISO 13849-1 |
Mission time | 20 Year(s) |
Safety classification - Safety outputs
B10D Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Latching force | 30 N |
Positive break travel | 8 mm |
Positive break force per NC contact, minimum | 10 N |
Positive break force, minimum | 10 N |
Actuating speed, maximum | 2 m/s |
Mounting | Screws |
Type of the fixing screws | 2x M6 |
Mechanical data - Connection technique
Cable entry | 3 x M16 x 1,5 |
Termination | Screw terminals |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Note | All indications including the conductor ferrules. |
Allowed type of cable | solid single-wire solid multi-wire flexible |
Mechanical data - Dimensions
Length of sensor | 30 mm |
Width of sensor | 52 mm |
Height of sensor | 75 mm |
Ambient conditions
Degree of protection | IP67 |
Ambient temperature | -30 ... +80 °C |
Storage and transport temperature | -40 ... +85 °C |
Permissible installation altitude above sea level, maximum | 2,000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui | 500 V |
Rated impulse withstand voltage Uimp | 6 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Electrical data
Thermal test current | 10 A |
Required rated short-circuit current | 1,000 A |
Switching element | 1 NO contact, 1 NC contacts |
Switching principle | slow action, positive break NC contact |
Maximum switching frequency | 4,000 /h |
Material of the contacts, electrical | Silver |
Electrical data - Safety contacts
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 4 A |
Scope of delivery
Scope of delivery | Actuator must be ordered separately. |
Tags:
HDL-DYT24062002