Product data sheet
Measuring principle
Conductivity
Applications
Water, sewage, processes, media separation, industrial water.
Features
Two electrode system for medium conductivity application range.
Measuring range
k=1: 10.0 µS/cm... .20.0 mS/cm
Measuring principle
Conductive conductivity sensor with graphite electrode for medium conductivity range.
Design
Two-electrode system, electrodes mounted side by side
Materials
Sensor rod: PES
Electrodes: Graphite
External dimensions
Diameter: 24 mm
(0.936 inch)
Length: 61 mm
(2.37 inch)
Process Temperature
Maximum 135°C
(275°F)
Process pressure
Maximum 16 bar at 20°С
(max. 232 psi at 68°F)
Temperature sensors
Optional Pt100 or PTC temperature sensor available
Ex approvals
ATEX
Connections
Process connection: DN25, DN40, G1"; cable: 4-pin connector with Pg9 thread or fixed cable.
Protection class
IP65 (connector), IP67 (integral cable)