Product data sheet
Specifications
Input
Pressure Range Vacuum to 6000 psi (400 bar)
Proof Pressure 4 x Full Scale (FS) (<1% FS Zero Shift)
Burst Pressure >35 x FS <= 60 psi (4 bar); >20 x FS <= 600 psi (40 bar); >5 x FS <= 6000 psi (400 bar)
Fatigue Life Designed for more than 100 million FS cycles
Performance
Supply Voltage Sensitivity 0.01% FS/Volt
Long Term Drift 0.2% FS/year (non-cumulative)
Accuracy 0.5% FS typical
Thermal Error 2.0% FS typical Compensated Temperatures -5°F to +180°F (-20°C to +80°C)
Operating Temperatures -40°F to +260°F (-40°C to +125°C) for elec. codes A, B, C, 1 -5°F to +180°F (-20°C to +80°C) for elec. codes 2, D, G, 3 -5°F to +125°F (-20°C to +50°C) for elec.
code F temperatures >100°C supply is limited to 24 VDC
Zero Tolerance 1% of span
Span Tolerance 1% of span
Response Time 0.5 ms
Mechanical Configuration
Pressure Port see ordering chart
Wetted Parts 17-4 PH Stainless Steel
Electrical Connection see ordering chart
Enclosure 316 SS, 17-4 PH ss IP65 NEMA 4 for elec. codes A,B,C,D,G,1,2,3 IP67 for elec. codes F IP30 for elec. code “3” with flying leads Vibration 70g, peak to peak sinusoidal, 5 to 2000 Hz (Random
Vibration: 20 to 200 Hz @ 20g Peak per MIL-STD.-810E Method 514.4)
Acceleration 100g steady acceleration in any direction 0.032% FS/g for 15 psi (1 bar) range decreasing logarithmically to 0.0007% FS/g for 6000 psi (400 bar) range.
Shock 20g, 11 ms, per MIL-STD.-810E Method 516.4 Procedure I
Approvals CE, UR (12 ET, 16 ET Intrinsically safe)
Weight approx. 100 grams (additional; cable 75 g/m
Individual Specifications
Voltage Output units Output See ordering chart Supply Voltage (Vs) 1.5 VDC above span to 35 VDC Min.
Load Resistance (FS output / 2) Kohms Current Output units Output 4-20 mA (2 wire) Supply Voltage (Vs) 24 VDC, (7-35 VDC) Max.
Loop Resistance (Vs-7) x 50 ohm