Product data sheet
Product characteristics
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
-1...10 bar
-14.6...145 psi
-0.1...1 MPa
Process connection
threaded connection G 1/4 Internal thread (DIN EN ISO 1179-2)
Application
System
gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
for industrial applications
Media
liquids and gases
Medium temperature [°C]
-25...80
Min. bursting pressure
150 bar
2175 psi
15 MPa
Pressure rating
75 bar
1087 psi
7.5 MPa
Vacuum resistance [mbar]
-1000
Type of pressure
relative pressure; vacuum
Electrical data
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
< 35
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
0.3
Integrated watchdog
yes
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs
2
Output signal
switching signal; analog signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / closed; (configurable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
250
Switching frequency DC [Hz]
< 500
Number of analog outputs
1
Analog current output [mA]
4...20; (scalable 1:5)
Max. load [Ω]
500
Analog voltage output [V]
0...10; (scalable 1:5)
Min. load resistance [Ω]
2000
Short-circuit protection
yes
Type of short-circuit protection
yes (non-latching)
Overload protection
yes
Measuring/setting range
Measuring range
-1...10 bar
-14.6...145 psi
-0.1...1 MPa
Analog start point
-1...8 bar
-14.6...116 psi
-0.1...0.8 MPa
Analog end point
1...10 bar
14.6...145 psi
0.1...1 MPa
Factory setting / CMPT = 2
Set point SP
-0.94...10 bar
-13.6...145 psi
-0.094...1 MPa
Reset point rP
-0.98...9.96 bar
-14.2...144.4 psi
-0.098...0.996 MPa
Min. difference between SP and rP
0.06 bar
0.6 psi
0.006 MPa
In steps of
0.02 bar
0.2 psi
0.002 MPa
Status_B High Resolution / CMPT = 3
Set point SP
-0.94...10 bar
-13.6...145 psi
-0.094...1 MPa
Reset point rP
-0.98...9.96 bar
-14.2...144.4 psi
-0.098...0.996 MPa
Min. difference between SP and rP
0.05 bar
0.6 psi
0.005 MPa
In steps of
0.01 bar
0.1 psi
0.001 MPa
Accuracy / deviations
Switch point accuracy [% of the span]
< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]
< ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]
< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]
< ± 0,2; (-0...80 °C)
Temperature coefficient span [% of the span / 10 K]
< ± 0,2; (-0...80 °C)
Notes on the accuracy / deviation
switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Reaction times
Response time [ms]
< 1.5
Delay time programmable dS, dr [s]
0...50
Damping process value dAP [s]
0...4
Damping for the analog output dAA [s]
0...4
Max. response time analog output [ms]
3
Software / programming
Parameter setting options
hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
SIO mode
yes
Required master port class
A; (when pin 2 not connected: B)
Supported DeviceIDs
Type of operation
DeviceID
Factory setting / CMPT = 2
463
Status_B High Resolution / CMPT = 3
974
Note
For further information please see the IODD PDF file at "Downloads"
Factory setting / CMPT = 2
Profiles
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms]
2.3
IO-Link resolution pressure [bar]
0.01
IO-Link process data (cyclical)
Function
bit length
pressure
14
binary switching information
2
IO-Link functions (acyclical)
application specific tag
Status_B High Resolution / CMPT = 3
Profiles
Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms]
3
IO-Link resolution pressure [bar]
0.005
IO-Link process data (cyclical)
Function
bit length
pressure
16
device status
4
binary switching information
2
IO-Link functions (acyclical)
application specific tag
Operating conditions
Ambient temperature [°C]
-25...80
Storage temperature [°C]
-40...100
Protection
IP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27
50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6
20 g (10...2000 Hz)
MTTF [years]
138
UL approval
UL approval number
J012
Pressure equipment directive
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]
239
Material
stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)
stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM
Min. pressure cycles
100 million
Tightening torque [Nm]
25...35; (recommended tightening torque; Depends on lubrication, seal and pressure rating)
Process connection
threaded connection G 1/4 Internal thread (DIN EN ISO 1179-2)
Restrictor element integrated
no (can be retrofitted)
Displays / operating elements
Display
Display unit
3 x LED, green (bar, psi, MPa)
Switching status
2 x LED, yellow
Measured values
alphanumeric display, red/green 4-digit
Remarks
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; coding: A; Contacts: gold-plated