Pressure sensor with display PN2070 PN-400-SER14-MFRKG/US/ /V

Pressure sensor with display PN2070 PN-400-SER14-MFRKG/US/ /V
Pressure sensor with display PN2070 PN-400-SER14-MFRKG/US/ /V
  • MODEL: PN2070 PN-400-SER14-MFRKG/US/ /V
  • LEAD TIME: 3-5days
$229.13

Product data sheet

Product characteristics
Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Measuring range
0...400 bar0...5800 psi0...40 MPa
Process connectionthreaded connection G 1/4 Internal thread (DIN EN ISO 1179-2)
Application
Systemgold-plated contacts
Measuring elementmetallic thin film cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature [°C]-25...80
Min. bursting pressure
1700 bar24650 psi170 MPa
Pressure rating
800 bar11580 psi80 MPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
Electrical data
Operating voltage [V]18...30 DC; (to SELV/PELV)
Current consumption [mA]< 35
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]0.3
Integrated watchdogyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analog signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250
Switching frequency DC [Hz]< 500
Number of analog outputs1
Analog current output [mA]4...20; (scalable 1:5)
Max. load [Ω]500
Analog voltage output [V]0...10; (scalable 1:5)
Min. load resistance [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Measuring/setting range
Measuring range
0...400 bar0...5800 psi0...40 MPa
Analog start point
0...320 bar0...4640 psi0...32 MPa
Analog end point
80...400 bar1160...5800 psi8...40 MPa
Factory setting / CMPT = 2
Set point SP
2.5...400 bar40...5800 psi0.25...40 MPa
Reset point rP
1...398.5 bar10...5780 psi0.1...39.85 MPa
Min. difference between SP and rP
2 bar30 psi0.2 MPa
In steps of
0.5 bar10 psi0.05 MPa
Status_B High Resolution / CMPT = 3
Set point SP
2.5...400 bar37...5802 psi0.25...40 MPa
Reset point rP
0.9...398.4 bar13...5778 psi0.09...39.84 MPa
Min. difference between SP and rP
1.7 bar24 psi0.17 MPa
In steps of
0.1 bar1 psi0.01 MPa
Accuracy / deviations
Switch point accuracy [% of the span]< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]0,2; (-25...80 °C)
Temperature coefficient span [% of the span / 10 K]0,2; (-25...80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Reaction times
Response time [ms]< 1.5
Delay time programmable dS, dr [s]0...50
Damping process value dAP [s]0...4
Damping for the analog output dAA [s]0...4
Max. response time analog output [ms]3
Software / programming
Parameter setting optionshysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port classA; (when pin 2 not connected: B)
Supported DeviceIDs
Type of operationDeviceID
Factory setting / CMPT = 2459
Status_B High Resolution / CMPT = 3638
Note
For further information pl