Menu
Your Cart

Pressure Sensor PY7002

Pressure Sensor  PY7002
Pressure Sensor PY7002
  • MODEL: PY7002
  • LEAD TIME: 3-4weeks
$527.03

Product data sheet

Product Characteristics

Total number of inputs and outputs

Number of digital outputs: 2

Measuring range

0.... .100 bar

0... .1450 psi .1450 psi

Measuring range [MPa]

0... .10

System connections

Flange Female thread: G 1/4; Female thread: M6

APPLICATIONS

Special features

Gold-plated contacts

Design

with flange adapter

Media

Liquid and gaseous media

Conditionally applicable

for gaseous media pressures > 25 bar only on request

Medium temperature [°C]

-25.... .80

Burst pressure min.

650 bar

9400 psi

Burst Pressure Min [MPa]

65

Compressive Strength

300 bar

4350 psi

Compressive Strength [MPa]

30

Pressure

Relative pressure

Electrical Data

Operating voltage [V]

18.... .36 DC; (according to SELV/PELV)

Current loss [mA]

< 50

Insulation resistance min.

100; (500 V DC)

Protection class

III

Inverted phase protection

yes

Overvoltage protection

Yes; (< 40 V)

Power-on delay time [s]

0.3

Watchdog

Yes

Total Inputs/Outputs

Total number of inputs and outputs

Number of digital outputs: 2

Outputs

Number of outputs

2

Output signals

Switching signal; IO-Link; (configurable)

Electrical design

PNP/NPN

Number of digital outputs

2

Output function

Normally open/closed; (parameterizable)

Switching output DC voltage drop maximum value [V]

2

Continuous current load of switching output DC [mA]

250

Switching frequency DC [Hz]

< 170

Short circuit protection

Yes

Type of short-circuit protection

Pulse

Measuring/setting range

Measuring range

0.... .100 bar

0.... .1450 psi

Measuring range [MPa]

0... .10

Switching point, SP

1.... .100 bar

20.... .1450 psi

Switching point, SP [MPa]

0.1.... .10

Recovery point, rP

0.5....99.5 bar .99.5 bar

10.... .1440 psi

Recovery Point, rP [MPa]

0.05.... .9.95

Setting step

0.5 bar

10 psi

Setting step [MPa]

0.05

Factory setting

SP1 = 25.0 bar

rP1 = 23.0 bar

SP2 = 75.0 bar

rP2 = 73.0 bar

Accuracy / Deviation

Switching point accuracy [% of measuring range value]

< ± 0,5

Repeatability [% of measuring range] < ± 0,1; (temperature fluctuations < 10 K)

< ± 0,1; (temperature fluctuations < 10 K)

Characteristic curve deviation [% of measuring range] < ± 0,5; (temperature fluctuations < 10 K)

< ± 0,5; (linearity, including hysteresis and repeatability, limit values according to DIN EN IEC 62828-1)

Hysteresis deviation [% of measuring range value] < ± 0,25

< ± 0,25

Stability over time [% of measuring range value] < ± 0,05; (% of measuring range value)

< ± 0,05; (every 6 months)

Temperature coefficient of zero [% of measured range value / 10 K]

0,2; (-20.... .80 °C)

Temperature coefficient range [% of measured range value / 10 K] 0,2; (-20...80 °C)

0,2; (-20... .80 °C) .80 °C)

Reaction time

Programmable delay time dS, dr [s]

0; 0,2... .50 .50

Software / Programming

Parameter setting

Hysteresis/Window; Normally open/closed; Diagnostic function; Output polarity; ON delay, OFF delay; Damping; Display unit

Interfaces

Communication Interface

IO-Link

Transmission type

COM2 (38,4 kBaud)

IO-Link revision

1.1

SDCI standards

IEC 61131-9 CDV

Outline

No profile

SIO Mode

Yes

Required mater port type

A

Analog process data

1

2-digit output process data

2

Process cycle minimum [ms]

2.3

Supported DeviceID

Operation mode

DeviceID

default

309

Operating conditions

Ambient temperature [°C]

-20.... .80

Storage temperature [°C]

-40.... .100

Enclosure protection class

IP 67

Certification/Testing

EMC Electromagnetic Compatibility

EN 61000-4-2 ESD

4 kV CD / 8 kV AD

EN 61000-4-3 HF EMF radiation

10 V/m

EN 61000-4-4 Burst

2 kV

EN 61000-4-5 Surge

0,5/1 kV

EN 61000-4-6 Conducted immunity to RF field induction

10 V

Shock resistance

DIN IEC 68-2-27

50 g (11 ms)

Vibration

DIN IEC 68-2-6

20 g (10.... .2000 Hz)

Pressurized Equipment Directive

good engineering practice; can be used for Group 2 fluids; on demand for Group 1 fluids

Mechanical Technical Data

Weight [g]

381.5

Material

Stainless steel (1.4301/304); PC; PBT; PEI; FKM

Material (wetted parts)

Steel (1.4104 / 430F); Ceramic; FKM

Switching life

100 million

System Interface

Flange Female thread: G 1/4; Female thread: M6

Integrated limiter element

No

Display/operating elements

Display

Display units

3 x LED, green

Switching status

2 x LED, yellow

Function display

Alphanumeric display, 4 digits

Measured values

Alphanumeric display, 4 digits

Comments

Packaging unit

1 piece

Electrical connection