Product data sheet
Product Characteristics
Electrical Design
NPN
Output Function
Normally open/closed; (optional)
Sensing distance [mm]
15
Housing
Rectangular
Dimensions [mm]
40 x 40 x 120
Electrical data
Operating voltage [V]
10.... .36 DC
Current loss [mA]
15; (24 V)
Protection class
II
Inverted phase protection
yes
Outputs
Electrical design
NPN
Output Function
Normally open/closed; (optional)
Switching output DC voltage drop max.
2.5
Continuous current load of switching output DC [mA]
250
Switching frequency DC [Hz]
350
Short-circuit protection
Yes
Short-circuit protection type
Pulse
Overload protection
Yes
Monitoring Range
Sensing distance [mm]
15
Actual sensing distance Sr [mm]
15 ± 10 %
Operating distance [mm]
0.... .12.1
Accuracy / Deviation
Calibration coefficient
Steel: 1 / Special steel: 0.7 / Brass: 0.4 / Aluminum: 0.3 / Copper: 0.2
Hysteresis [% of Sr]
1.... .15
Switching point offset [% of Sr] -10... .15
-10.... .10
Operating conditions
Ambient temperature [°C]
-25.... .80
Enclosure protection class
IP 65
Certificates/Tests
EMC Electromagnetic Compatibility
EN 60947-5-2
EN 55011
Class B
MTTF [years]
1844
Mechanical Technical Data
Weight [g]
195
Housing
Rectangular
Mounting
flush mounting
Dimensions [mm]
40 x 40 x 120
Material
PPE modified
Display/operating elements
Display
Switch status
1 x LED, red
Comments
Annotation
5 positions of the active area are selectable
Packaging unit
1 piece
Electrical Connection
Connector
Terminal block: .... .2.5 mm²; Cable sheath: Ø 7..... .13 mm