Product characteristics
Output function | normally closed |
---|
Sensing range [mm] | 2 |
---|
Housing | rectangular |
---|
Dimensions [mm] | 40 x 12 x 26 |
---|
Electrical data
Operating voltage [V] | 20...250 AC/DC |
---|
Protection class | II |
---|
Reverse polarity protection | yes |
---|
Outputs
Output function | normally closed |
---|
Max. voltage drop switching output DC [V] | 6 |
---|
Max. voltage drop switching output AC [V] | 6.7 |
---|
Minimum load current [mA] | 5 |
---|
Max. leakage current [mA] | 2.0 (250 V AC) / 1.3 (110 V AC) / 0.8 (24 V DC) |
---|
Permanent current rating of switching output AC [mA] | 250; (350 (...50 °C)) |
---|
Permanent current rating of switching output DC [mA] | 100 |
---|
Short-time current rating of switching output [mA] | 2200; (50 ms / 1 Hz) |
---|
Switching frequency AC [Hz] | 25 |
---|
Switching frequency DC [Hz] | 50 |
---|
Short-circuit proof | no |
---|
Overload protection | no |
---|
Monitoring range
Sensing range [mm] | 2 |
---|
Real sensing range Sr [mm] | 2 ± 10 % |
---|
Operating distance [mm] | 0...1.6 |
---|
Accuracy / deviations
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.25 / aluminum: 0.2 / copper: 0.05 |
---|
Hysteresis [% of Sr] | 1...20 |
---|
Switch-point drift [% of Sr] | -10...10 |
---|
Operating conditions
Ambient temperature [°C] | -25...80 |
---|
Protection | IP 67 |
---|
Tests / approvals
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 3 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-6 HF conducted | 3 V | EN 55011 emission | class B |
|
---|
MTTF [years] | 612 |
---|
Mechanical data
Weight [g] | 104.7 |
---|
Housing | rectangular |
---|
Mounting | flush mountable |
---|
Dimensions [mm] | 40 x 12 x 26 |
---|
Material | PBT |
---|
Mounting hole
Tightening torque [Nm] | < 0.5 |
---|
Threaded bush
Tightening torque [Nm] | < 1.2; (when brass insert in contact with counterpart) |
---|
Displays / operating elements
Display | Switching status | 1 x LED, yellow |
|
---|
Electrical connection
Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
---|
Remarks
Remarks | Recommendation: check the unit for reliable function after a short circuit. |
|
---|
Pack quantity | 1 pcs. |
---|
Electrical connection
Connection | Cable: 2 m, PVC; 2 x 0.5 mm² |
---|