Product data sheet
Product Characteristics
Number of Inputs/Outputs
Analog output: 1
Process connection
Pressure contact G 1/4 threaded thread
Application
Features
Gold-plated contacts
Applications
Industrial Applications
Media
Liquids and gases
Conditions of use
For use with gases exceeding 2.5 MPa, the product must be made to order only.
Media temperature [°C]
-25 to 90, (on request: -40 to 90 °C)
Minimum breakdown pressure [MPa]
100
Maximum permissible pressure [MPa]
60
Pressure type
Gauge pressure
Electrical Specifications
Operating supply voltage range [V]
DC 9.6 to 32
Insulation resistance [MΩ]
100, (DC 500 V)
Protection class
III
Reverse connection protection
Yes
Inputs / Outputs
Number of inputs / outputs
Analog output: 1
Number of outputs
Maximum number of outputs
1
Output Signal
Analog signal
Analog output
1
Current output [mA]
4 to 20
Max. load [Ω]
720, (Ub = 24 V, (Ub - 9.6 V) / 20 mA)
Overload protection circuit
Yes
Measuring range / setting range
Measuring range [MPa]
0 to 40
Accuracy / Error
Repeatability [% of span] < 0.1, (for temperature variation < 10 K)
< 0.1, (for temperature variation < 10 K)
Overall accuracy [% of span] < ± 0.25 (BFSL)
< ± 0.25 (BFSL) / < ± 0.5 (LS), (BFSL = Best Fit Straight Line, LS = Limit Setting)
Long-term stability [% of span]
< ± 0.05, (every 6 months)
Temperature drift (TEMPCO) Zero point error [% / 10 K] <
0.1, (0 to 80 °C)
Temperature drift (TEMPCO) span error [% / 10 K] 0.2, (0 to 80 °C)
0.2, (0 to 80 °C)
Response time
Response time of analog output [ms]
3
Ambient operating conditions
Ambient operating temperature [°C]
-25 to 80
Storage temperature [°C]
-40 to 100
Protective structure
IP 68, IP 69K
Tests / Certifications
EMC
EN 61000-4-2 ESD
4 kV CD / 8 kV AD
EN 61000-4-3 High frequency radiation
30 V/m
EN 61000-4-4 Burst
2 kV
EN 61000-4-6 Withstand high-frequency inductive coupling
10 V
Radiated disturbance immunity
According to EU Automotive Directive 2004/104/EC
CISPR 25
Noise immunity
According to EU Automotive Directive 2004/104/EC
ISO 11452-2 High frequency radiation
100 V/m
ISO 7637-2 pulse
Severity level 4
Shock resistance
DIN EN 60068-2-27
50 (x 9.81 m/s²) (11 ms)
DIN EN 61373
Category 3
Vibration resistance
DIN EN 60068-2-6
20 (x 9.81 m/s²) (10 to 2000 Hz)
DIN EN 61373
Category 2
MTTF [years]
555
Pressure Equipment Directive
Sound engineering practice, available for PED fluid group 2, fluid group 1 on request
Railroad applications
DIN EN 50155 / IEC 60571
Klasse T3, C1, S1
Mechanical Specifications
Weight [g]
222.5
Material
Stainless steel 1.4404 (SUS316L), FKM , PA, EPDM/X
Material of media contact area
Stainless steel 1.4305 (SUS303), Ceramic, FKM
Minimum switching frequency
100 million cycles