Product data sheet
Input
Input Voltage • 90-264 VAC, 120-375 VDC (DNR05/10/18)
85-264 VAC, 90-375 VDC (DNR30/60)
Input Frequency • 47-63 Hz
Input Current • See tables
Inrush Current • 5-18 W: 15/30 A at 115/230 VAC
30 W: 20/40 A at 115/230 VAC
60 W: 30/60 A at 115/230 VAC
Power Factor • EN61000-3-2, class A
Earth Leakage Current • 0.8 mA max
Input Protection • Internal fuse T2A, 250 VAC fitted in line
Output
Output Voltage • See tables
Output Voltage Trim • See tables
Initial Set Accuracy • ±1%
Minimum Load • No minimum load required
Start Up Delay • <1 s (may increase at low
temperature extremes)
Start Up Rise Time • <150 ms
Hold Up Time • 30/130 ms at 115/230 VAC (DNR05)
25/100 ms at 115/230 VAC (DNR10)
20/75 ms at 115/230 VAC (DNR18)
20/30 ms at 115/230 VAC (DNR30)
20/30 ms at 115/230 VAC DNR60)
Line Regulation • 5-18 W: ±1.0% max
30-60 W: ±0.5% max
Load Regulation • 5-18 W: ±2.0% max
30-60 W: ±0.5% max
Parallel Operation • Redundancy module DPM10 available
for load currents up to 10 A (not with
standby system), contact sales
Transient Response • 4% max deviation recovery to within
1% in 2 ms for a 50% load change
Ripple & Noise • 50 mV pk-pk, 20 MHz bandwidth (may
increase at low temperature extremes)
Overvoltage Protection • Output clamps at 120-145% Vnom,
auto recovery
Overload Protection • 110-165% constant current (DNR05-18)
105-150% power limited (DNR30/60)
Short Circuit Protection • Power limited, auto recovery
Temperature • ±0.03%/°C
Coefficient
xppower.com
General
Efficiency • See tables
Isolation • 3000VAC Input to Output, 1500VAC Input
to Ground, 500VAC Output to Ground
Switching Frequency • 132 KHz typical, 55-90 kHz (DNR60)
Signals • DC ON indicator LED Green: All models
DC LOW indicator LED Red: 5-18 W models
DC OK: 24 V 30-60 W models
DC OK: All standby models
MTBF • 800 kHrs typical Bellcore, Issue 6 at +40 °C,
GB (DNR05/10/18), 530 kHrs typical
Bellcore, Issue 6 at +40 °C, GB (DNR30/60)
DIN Rail • Compatible with TS35/7.5 or TS35/15
Environmental
Operating Temperature • -20 °C to +70 °C (DNR05/10/18)
-40 °C to +70 °C, start up at -35 °C
(DNR30/60), all units derate linearly from
60 °C (see derating curves)
Cooling • Convection-cooled with 25mm free space
all sides
Operating Humidity • 20-95% RH, non-condensing
Storage Temperature • -25 °C to +85 °C (DNR05/10/18)
-40 °C to +85 °C (DNR30/60)
Shock • 15 g, 11 ms, X,Y & Z axis, 3 shocks/axis in
both directions
Vibration • 2 g, 10 Hz to 500 Hz, along X,Y & Z axis,
60 mins/axis, mounted on rail
EMC & Safety
Emissions • EN55022, level B conducted & radiated
Harmonic Currents • EN61000-3-2, class A
Voltage Flicker • EN61000-3-3
ESD Immunity • EN61000-4-2, level 4, Perf Criteria A
Radiated Immunity • EN61000-4-3, level 3, Perf Criteria A
EFT/Burst • EN61000-4-4, level 4, Perf Criteria A
Surge • EN61000-4-5, installation class 3,
Perf Criteria A
Conducted Immunity • EN61000-4-6, level 3, Perf Criteria A
Magnetic Field • EN61000-4-8, level 4 Perf Criteria A
Dips & Interruptions • EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
Safety Approvals • EN60950-1, UL508 Pollution Degree 2,
UL1310 class 2 power recognised,
See note 3 & ratings table,
UL60950-1 Overvoltage Category II,
UL508 Overvoltage Category III,
DNR30 & DNR60: SEMI F47
ANSI/ISA 12.12.01. Class 1, Division 2
Groups A,B,C and D