Product No. : CPS11-2BA2ESAMeasuring Principle:Glass electrodeApplication:Standard applications in process and the environment. Long-term monitoring, processes with little change.Characteristic:Very robust, heavy-duty version / high pressure, integrated potential matching, flat membrane availab..
Installation locationOptionalMinimum Grab Time10 msContinuous power on rate100%Characteristic parameters of the coil24 V DC: 4.5 WPermissible voltage fluctuations+/- 10 %CE certification (see declaration of conformity)Compliant with the EU Explosion Protection Directive (ATEX)EU overseas explosion-p..
Installation locationOptionalSwitch position indicatornoMinimum Grab Time10 msContinuous power on rate100%Power factor (cos phi)zero point sevenCharacteristic parameters of the coil230 V AC: 50/60 Hz, starting power 9.0 Va, maintaining power 7.0 VAPermissible frequency fluctuations+/-5%Permissible v..
Product CharacteristicsTotal number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1Measuring range5.... .3000 ml/min0.005... .3 l/min .3 l/minSystem connectionsThreaded connection G 1/4 DN6 flat sealApplicationsSpecial propertiesGold-plated contactsApplicationsAdder fu..
DESCRIPTION Data sheetType ESX10-T. expands our product range of electronic overcurrent protection for DC 24 V applications.It provides selective protection of all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by active current limitation in the event of a short circuit and..
Number of inputs and outputsNumber of digital outputs: 2Factory settingautomatic medium detectionProbe length L [mm]472ApplicationSystemgold-plated contactsMediahydrous coolants; oils; oil-based media; water; media similar to waterDielectric constant of the medium> 2Cannot be used forextremely co..
Range of productEOCRDevice short nameEOCR-3D420product or component typeProtection relayProtection typeOverload, In > OC settingSensitivity to phase lossSensitivity to phase reverseLocked rotor, In > 3 times OC settingPhase unbalance, 50 %Product specific applicationOvercurrent protectionAnalo..
Product Application ProtectionRelay applications Locked rotor, mechanical blocking I > 3 x I SettingOverload Imax > IsettingSensitivity to phase faultsNominal supply voltage [Us] 200.... .240 V ACRelay setting range 5...60 ARated insulation voltage [Ui] Power supply circuit: 600 V AC in accord..
Voltage 9-15Vdc 18-28Vdc
Current 40mA (Typical Tone 3)
Sound Output 106dB(A) (Typical Tone 3)
Tones 32
Volume Control 10dB
Monitoring Reverse polarity
Temperature - 25ºC to + 70ºC
Protection IP54 (s)* IP65 (d)*
Construction ABS
Weight 0.25Kg
Colours Red or white ..