Installation locationOptionalStructural characteristicsBranch moduleSymbol00991511working pressure0.02 Mpa ... 1.6 Mpaworking pressure0.2 bar ... 16 barStandard nominal flow rate in the main airflow direction 1->25100 l/minWorking mediumCompressed air, in accordance with ISO 8573-1:20..
Mounting positionAnyStructural designBranching moduleSymbol00991510Operating pressure0 MPa ... 1.6 MPaOperating pressure0 bar ... 16 barStandard nominal flow rate in main flow direction 1 -> 28200 l/minOperating mediumCompressed air as per ISO 8573-1:2010 [7:-:-]
Inert gasCorrosion resistance cl..
ProductArticle Number (Market Facing Number)3VA2463-5HM32-0AA0Product Descriptioncircuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU330, LIG, In=630 A overload protection Ir=250 A...630 A short-circuit protection Ii=1.5...9x In ground-fault prot..
Key messagesProduct family TeSys DecaThe product name is TeSys GV2 TeSys DecaProduct type: Motor circuit breakerThe short name of the product is GV2PThe product applies motor protectionTripper type: thermomagneticNumber of poles 3PGrid type ACUse Category AC in accordance with IEC 60947-2 ..
TechnicalCurrent Type:ACElectrical Durability:Ue =< 440 V 8000 cycleUe = 500 ... 690 V 8000 cycle30 cycles per hourMechanical Durability:20000 cycle60 cycles per hourNeutral Pole Current ([%Iu]):100 %Number of Poles:4Power Loss:100 WRated Current (In):800 ARated Impulse Withstand Voltage (Uimp):a..
Technical characteristicsBuilt-in depth 44 mmRelease characteristic CNumber of poles (total) 1Number of protected poles 1Rated current 6 ARated voltage 230 VRated insulation voltage Ui 500 VRated impulse withstand voltage Uimp 4 kVRated short-circuit breaking capacity Icn according to EN 60898 at 23..
Grid frequency50/60 HzRated operating voltage [Ue]230 V AC 50/60 HzMagnetic release limit5.... .10 x InCurrent limiting class3Rated insulation voltage [Ui]500 V ACRated withstand voltage [Uimp]6 kVContact position indicationyesControl typeHandleLocal signal indicationOn/Off indicationMounting TypeLo..
Grid frequency50/60 HzRated working voltage [Ue]400 V AC 50/60 HzMagnetic release limit10.... .14 x InCurrent limiting class3Rated insulation voltage [Ui]500 V ACRated withstand voltage [Uimp]6 kVContact position indicationyesControl typeHandleLocal signal indicationOn/Off indicationMounting TypeLoc..
Grid frequency50/60 HzRated working voltage [Ue]400 V AC 50/60 HzMagnetic disconnection limit10.... .14 x InCurrent limiting class3Rated insulation voltage [Ui]500 V ACRated withstand voltage [Uimp]6 kVContact position indicationyesControl typeHandleLocal signal indicationOn/Off indicationMounting T..
[Ui] rated insulation voltage800 V AC 50/60 Hz[Uimp] rated impulse withstand voltage8 kV[Ics] rated service short-circuit breaking capacity90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 6094..
Technical ParametersStandard: IEC/EN 60898-1IEC/EN 60898-1IEC/EN 60947-2UL 1077Tripping CharacteristicsCRated operating voltage: acc. to IEC 60898-1 400 V ACacc. to IEC 60898-1 400 V ACacc. to IEC 60898-1 400 V ACacc. to IEC 60947-2 440 V ACOperating voltage: Maximum (Incl. Tolerance)Maximum (Incl. ..