Product data sheet
- Width64.8 mm
- Length107.3 mm
- Reverse polarity protectionFor operating voltage
- Mounting positionoptional
- DiagnosisUndervoltage of load supplies
- Max. number of valve positions32
- Valve terminal structureValve sizes can be mixed
- Max. number of valve coils32
- Operating pressure-0.09 MPa ... 1 MPa
- Operating pressure-0.9 bar ... 10 bar
- Pilot pressure0.3 MPa ... 0.8 MPa
- Pilot pressure3 bar ... 8 bar
- Internal current consumption, load voltage30 mA
- Internal current consumption, operating voltage30 mA
- Nominal operating voltage DC24 V
- ProtocolI-Port IO-Link®
- Corrosion resistance class CRC3 - high corrosion stress
- LABS (PWIS) conformityVDMA24364-B1/B2-L
- Storage temperature-20 °C ... 40 °C
- Degree of protectionIP65 IP67
- Note on degree of protectionIn assembled state
- Ambient temperature-5 °C ... 50 °C
- Product weight170 g
- IO-Link, Protocol versionDevice V 1.0
- IO-Link, communication modeCOM2 (38.4 kBaud), COM3 (230.4 kBaud)
- IO-Link, Port classB
- IO-Link, Number of ports1
- IO-Link, Process data length OUT1 - 4 bytes
- IO-Link, Min. cycle timeDevice 3.2 ms
- Electrical connection 1, functionIO-Link
- Electrical connection 1, connection typePlugs
- Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
- Electrical connection 1, number of connections/cores5
- Electrical connection 1, connection pattern00995383
- LED display, bus-specific1x communication status
- Note on materialsRoHS-compliant
- Material end platePPA reinforced
Tags:
HENJ-DMG24080805