Number of Poles 1PApplication Power Distribution ProtectionNumber of protection poles 1Rated current [In] 6 A at 30 °C on ...Grid type ACType of release Thermo-magneticTripping curve CBreaking capacity 6 kA Icn at ... 230 V AC 50/60 Hz in accordance with GB/T 10963.16 kA Icn on ... 230 V AC 50/60 Hz..
Number of Poles 3PApplication Power Distribution ProtectionNumber of poles 3Nominal current [In] 16 A at 30 °C on ...Grid type ACType of release Thermo-magneticTripping curve CBreaking capacity 6 kA Icn at ... 400 V AC 50/60 Hz per pole in accordance with GB/T 10963.16 kA Icn on ... 400 V AC 50/60 H..
Network frequency 50/60 HzMagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breakingcapacity21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz5 kA..
poles description 3PNumber of protected poles 3[In] rated current 32 Anetwork type ACDCTrip unit technology Thermal-magneticCurve code Cnetwork frequency 50/60 HzMagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breakingcapacity15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz7...
Number of Poles 2PNeutral position leftRated current [In] 40 AGrid type ACResidual current sensitivity 30 mASelectivity of residual current action protection Instantaneous typeLeakage current protection class ADistribution system location Downstream distribution outletsGrid frequency 50 HzRated oper..
Device application Motor protectionpoles description 3PProtected poles description 3D[In] rated current 6.3 A at 65 °C[Ue] rated operational voltage 690 V AC 50/60 Hznetwork type ACnetwork frequency 50/60 HzSuitability for isolation Yes conforming to EN/IEC 60947-2Utilisation category Category A[Icu..
Product Type Circuit BreakerApplication Power Distribution ProtectionNumber of Poles 3PDescription of protection poles 3DRated current [In] 160 A at ... up 40 °CRated operating voltage [Ue] 690 V AC 50/60 HzGrid type ACGrid frequency 50/60 HzIsolation function Applicable Conforms to TM-DClass of use..
Number of poles 3PDescription of protection poles 3DNominal current [In] 250 A at 40 °C onRated operating voltage [Ue] 690 V AC 50/60 HzGrid type ACGrid frequency 50/60 HzIsolation function Applicable Conforms to TM-DClass of use AC[Icu] Rated ultimate short-circuit breaking capacity 85 kA Icu on 22..
Number of poles 3PProtected poles description 3t[In] rated current 63 A at 40 °C[Ue] rated operational voltage 690 V AC 50/60 Hznetwork type ACnetwork frequency 50/60 HzSuitability for isolation Yes conforming to EN/IEC 60947-2Utilisation category Category A[Icu] rated ultimate short-circuitbreaking..
DimensionsProduct Net Width:45 mmProduct Net Height:90 mmProduct Net Depth / Length:85.6 mmProduct Net Weight:0.225 kgTechnicalRated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 50 kA(400 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 30 kA(690 V AC) 30 kARated Ultimate Short-Circuit Breaking Cap..
Electrical Durability:5000 cycle60 cycles per hourMechanical Durability:20000 cycle120 cycles per hourNumber of Poles:3Power Loss:at Rated Operating Conditions per Pole 41 WProduct Main Type:SACE Tmax TProduct Name:Moulded Case Circuit BreakerProduct Type:Automatic Circuit BreakerRated Current (In):..
Circuit breaker, ComPacT NSX100HB1, 75kA/690VAC, 3 poles, MicroLogic 2.2 trip unit 100ARangeComPacT new generationProduct nameComPacT NSX new generationDevice short nameNSX100HB1product or component typeCircuit breakerDevice applicationDistributionpoles description3PProtected poles description3D[In]..
Standards:IEC/EN 60898-1IEC/EN 60947-2UL 1077Tripping Characteristic:CRated Operational Voltage:acc. to IEC 60898-1 230 / 400 V ACacc. to IEC 60898-1 230 Vacc. to IEC 60947-2 230 V ACOperational Voltage:Maximum (Incl. Tolerance) 253 V ACMaximum (Incl. Tolerance) 72 V DCMinimum 12 V ACMinimum 12 V DC..
Standards:IEC/EN 60898-1IEC/EN 60947-2UL 1077Tripping Characteristic:CRated Operational Voltage:acc. to IEC 60898-1 400 V ACacc. to IEC 60898-1 400 Vacc. to IEC 60947-2 440 V ACOperational Voltage:Maximum (Incl. Tolerance) 125 V DCMaximum (Incl. Tolerance) 440 V ACMinimum 12 V ACMinimum 12 V DCRated..