Delivery informationExport Control RegulationsAL : N / ECCN : NEstimated dispatch time (Working Days)5 Day/DaysNet Weight (kg)0,344 KgPackaging Dimension49,00 x 102,00 x 102,00Package size unit of measureMMQuantity Unit1 PiecePackaging Quantity1Additional Product InformationEAN4011209712416UPC662643..
insulation voltage / rated value 800 Voperating voltage / at DC / rated value 500 Voperating voltage / at AC / rated value 690 Vpower loss [W] / maximum 25 Wmechanical service life (operating cycles) / typical 20 000electrical endurance (operating cycles) / at AC-1 / at 380/415 V 9 000electrical end..
ProductArticle Number (Market Facing Number)3VL7712-1AA36-0AA0Product Descriptioncircuit breaker VL1250N w/o Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 3-pole In=< 1250A, rated current without auxiliary release with screw terminal connections for switching unit and ETUProdu..
Number of Poles 1PApplication Power Distribution ProtectionNumber of protection poles 1Rated current [In] 6 A at 30 °C on ...Grid type ACType of release Thermo-magneticTripping curve CBreaking capacity 6 kA Icn at ... 230 V AC 50/60 Hz in accordance with GB/T 10963.16 kA Icn on ... 230 V AC 50/60 Hz..
Number of Poles 3PApplication Power Distribution ProtectionNumber of poles 3Nominal current [In] 16 A at 30 °C on ...Grid type ACType of release Thermo-magneticTripping curve CBreaking capacity 6 kA Icn at ... 400 V AC 50/60 Hz per pole in accordance with GB/T 10963.16 kA Icn on ... 400 V AC 50/60 H..
Network frequency 50/60 HzMagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breakingcapacity21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz5 kA..
poles description 3PNumber of protected poles 3[In] rated current 32 Anetwork type ACDCTrip unit technology Thermal-magneticCurve code Cnetwork frequency 50/60 HzMagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breakingcapacity15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz7...
Number of Poles 2PNeutral position leftRated current [In] 40 AGrid type ACResidual current sensitivity 30 mASelectivity of residual current action protection Instantaneous typeLeakage current protection class ADistribution system location Downstream distribution outletsGrid frequency 50 HzRated oper..
Device application Motor protectionpoles description 3PProtected poles description 3D[In] rated current 6.3 A at 65 °C[Ue] rated operational voltage 690 V AC 50/60 Hznetwork type ACnetwork frequency 50/60 HzSuitability for isolation Yes conforming to EN/IEC 60947-2Utilisation category Category A[Icu..
Product Type Circuit BreakerApplication Power Distribution ProtectionNumber of Poles 3PDescription of protection poles 3DRated current [In] 160 A at ... up 40 °CRated operating voltage [Ue] 690 V AC 50/60 HzGrid type ACGrid frequency 50/60 HzIsolation function Applicable Conforms to TM-DClass of use..
Number of poles 3PDescription of protection poles 3DNominal current [In] 250 A at 40 °C onRated operating voltage [Ue] 690 V AC 50/60 HzGrid type ACGrid frequency 50/60 HzIsolation function Applicable Conforms to TM-DClass of use AC[Icu] Rated ultimate short-circuit breaking capacity 85 kA Icu on 22..
Number of poles 3PProtected poles description 3t[In] rated current 63 A at 40 °C[Ue] rated operational voltage 690 V AC 50/60 Hznetwork type ACnetwork frequency 50/60 HzSuitability for isolation Yes conforming to EN/IEC 60947-2Utilisation category Category A[Icu] rated ultimate short-circuitbreaking..
DimensionsProduct Net Width:45 mmProduct Net Height:90 mmProduct Net Depth / Length:85.6 mmProduct Net Weight:0.225 kgTechnicalRated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 50 kA(400 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 30 kA(690 V AC) 30 kARated Ultimate Short-Circuit Breaking Cap..