Menu
Your Cart

Drives VFD ATV930D45N4

Drives VFD ATV930D45N4
Drives VFD ATV930D45N4
  • MODEL: ATV930D45N4
  • Weight: 30.00kg
  • LEAD TIME: in stock
$1,730.00

Product data sheet

Main
Range of ProductAltivar Process ATV900
Device ApplicationIndustrial Application
Product or Component TypeVariable speed drive
product destinationSynchronous motors
Asynchronous motors
Product Specific ApplicationProcess for industrial
variantStandard version
With braking chopper
Phase3 phase
Mounting ModeWall mount
Communication Port ProtocolEtherNet/IP
Modbus serial
Modbus TCP
[Us] rated supply voltage380...480 V - 15...10 %
Motor power kW45.0 kW normal duty
37.0 kW heavy duty
Continuous output current88 A 4 kHz normal duty
74.5 A 4 kHz heavy duty
EMC filterIntegrated
With EMC plate option
IP degree of protectionIP21
Degree of protectionUL type 1
option moduleSlot A communication module Profibus DP V1
Slot A communication module PROFINET
Slot A communication module DeviceNet
Slot A communication module EtherCAT
Slot A communication module CANopen daisy chain RJ45
Slot A communication module CANopen SUB-D 9
Slot A communication module CANopen screw terminals
Slot A/slot B/slot C digital and analog I/O extension module
Slot A/slot B/slot C output relay extension module
Slot B 5/12 V digital encoder interface module
Slot B analog encoder interface module
Slot B resolver encoder interface module
communication module Ethernet Powerlink
Discrete input logic16 preset speeds
Asynchronous motor control profileConstant torque standard
Optimized torque mode
Variable torque standard
Synchronous motor control profilePermanent magnet motor
Synchronous reluctance motor
Maximum output frequency599 Hz
Switching frequency2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency4 kHz
Line current79.8 A 380 V normal duty)
67.1 A 380 V heavy duty)
69.1 A 480 V normal duty)
59.0 A 480 V heavy duty)
Apparent power57.4 kVA 480 V normal duty)
49.1 kVA 480 V heavy duty)
Maximum transient current105.6 A 60 s normal duty)
111.8 A 60 s heavy duty)
Network Frequency50-60 Hz
Prospective line Isc50 kA

Complementary
Discrete input number10
Discrete input typeDI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Discrete output number2
Discrete output typeLogic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Relay output number3
Relay output typeConfigurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
Maximum switching currentRelay output R1 resistive, cos phi = 1 3 A 250 V AC
Relay output R1 resistive, cos phi = 1 3 A 30 V DC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
Relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching currentRelay output R1, R2, R3 5 mA 24 V DC
Physical interfaceEthernet
2-wire RS 485
Connector Type2 RJ45
1 RJ45
Method of accessSlave Modbus TCP
Transmission Rate10, 100 Mbits
4.8 kbps
9600 bit/s
19200 bit/s
Transmission frameRTU
Number of addresses1…247
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance
4 quadrant operation possibleTrue
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Motor slip compensationAutomatic whatever the load
Adjustable
Not available in permanent magnet motor law
Can be suppressed
Braking to standstillBy DC injection
Brake chopper integratedTrue
Maximum Input Current per Phase79.8 A
Maximum output voltage480.0 V
Relative symmetric network frequency tolerance5 %
Base load current at high overload74.5 A
Base load current at low overload88.0 A
Power dissipation in WNatural convection 121 W 380 V 4 kHz
Forced convection 943 W 380 V 4 kHz
With safety function Safely Limited Speed (SLS)True
With safety function Safe brake management (SBC/SBT)True
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)True
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)True
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeThermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set1
Width8.9 in (226 mm)
Height26.5 in (673 mm)
Depth