Product data sheet

Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Control Circuit Voltage (Uc):
230 V
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NO) 63 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NO 30 A
(400 V) Three Phase, NO 30 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NO 14.5 kW
(400 V) Three Phase, NO 43.6 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NO 5 kW
(400 V) Three Phase, NO 15 kW
Rated Operational Current AC-7a (Ie):
(NO) 63 A
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NO 14.5 kW
(400 V) Three Phase, NO 43.6 kW
Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NO 30 A
(400 V) Three Phase, NO 30 A
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NO 5 kW
(400 V) Three Phase, NO 15 kW
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Rated Impulse Withstand Voltage (Uimp):
6 kV
Rated Insulation Voltage (Ui):
500 V
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.0 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 13 mm
Degree of Protection:
IP20
Electrical Durability:
AC-1 (NO) 100000 cycle
AC-3 (NO) 240000 cycle
AC-7a (NO) 100000 cycle
AC-7b (NO) 240000 cycle
Mechanical Durability:
1000000 cycle
Number of Poles:
4
Number of Auxiliary Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Main Contacts NC:
0
Number of Main Contacts NO:
4
Width in Number of Modular Spacings:
3.0
Pollution Degree:
3
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NO 5 Hp
(220 ... 240 V AC) Three Phase, NO 10 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(440 ... 480 V AC) Three Phase, NO 15 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-4 AWG
Stranded 16-4 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb