Product data sheet
- Valve function5/2 or 3/2, monostable
- Actuation typeElectrical
- Width53 mm
- Standard nominal flow rate900 l/min
- Pneumatic working portSub-base
- Operating voltageVia solenoid coil, to be ordered separately
- Operating pressure0.2 MPa ... 1 MPa
- Operating pressure2 bar ... 10 bar
- Structural designPlate seat
- Reset methodMechanical spring
- CE marking (see declaration of conformity)as per EU explosion protection directive (ATEX)
- Explosion protection certification outside the EUEPL Db (GB) EPL Gb (GB)
- UKCA marking (see declaration of conformity)acc. to UK EX instructions
- ATEX category gasII 2G
- ATEX category for dustII 2D
- Type of ignition protection for gasEx h IIC T6 Gb
- Type of (ignition) protection for dustEx h IIIC T70°C Db
- Explosive ambient temperature-5°C <= Ta <= +40°C
- Nominal width7 mm
- Exhaust air functionWith flow control option
- Sealing principleSoft
- Mounting positionAny
- Conforms to standardVDI/VDE 3845 (NAMUR)
- Manual overrideDetenting Non-detenting
- Type of controlPilot-controlled
- Flow directionNon-reversible
- Symbol00991831
- LapUnderlap
- b-value0.33
- C value4.2 l/sbar
- Switching time off100 ms
- On switching time50 ms
Tags:
ZORX-CJ24061906