Safety technical parameters
Safety integrity level SIL3 (IEC 61508)
Category category 4 (EN ISO 13849)
Performance class PL e (EN ISO 13849)
PFHD (Critical Failure Rate per Hour) 3.0 x 10-8 (EN ISO 13849)
TM (Continuous Operation) 20 years (EN ISO 13849)
B10d value switching operation 1 x 106 (AC-15, 230 V, I = 0,5 A )
Switching operation 3.5 x 105 (DC-13, 24 V, I = 2 A )
Switching operation 1.2 x 106 (DC-13, 24 V, I = 0,5 A)
Stop category 0 (EN 60204-1)
Electrical parameters
Operational data
Voltage supply A1, A2
Output current path > 25 V AC / 60 V DC PELV (protection against extra low voltage)
Output current path ≤ 25 V AC / 60 V DC PELV (protection extra low voltage) or SELV (safe extra low voltage)
Supply voltage Uv A1, A2
24 V DC (20.4 V DC ... 26.4 V DC)
Residual Ripple (≤ 2.4 Vss) 1)
Power consumption (≤ 1 W (DC))
Overvoltage category II
Rated insulation voltage Ui 300 V AC
Rated impulse withstand voltage Uimp 4 kV
Detection voltage: 2 kV (50 Hz) (EN 60439-1.)