Product data sheet
Input Current
From backplane bus DC 5 V, typical 15 mA
Output voltage/header
Measurement of the inverter supply voltage / heading
Supply current, max. 25 mA
Power loss
Power loss, typical 1.5 W
Analog Inputs
Number of analog inputs 0
Analog Outputs
Number of analog outputs 1
Cycle time (all channels), maximum Voltage: 300 μS (R), 750 μS (1 uF) Current: 600 μS (1 mH), 2 ms (10 mH)
Output Range, Voltage
Output range, voltage: -10 V to +10 V Yes
Output range, voltage ● -10 V to +10 V Yes
Output range, voltage ● -10 V to +10 V Yes Output range, current ● 0 to 20 mA Yes
Load resistance (within rated output range)
● Maximum 1 000 Ω for the voltage outputs
Maximum value for current output 600 Ω
Lead wire length
● Shielded, max. 100 m; shielded twisted-pair cable
Analog value composition of the outputs
Conversion principle Differential
Integration and conversion time/resolution per channel
Resolution with overmodulation (number of bits including sign), max. 12 bit
Error/accuracy
Temperature error (output range dependent), (+/-) 25 °C ±0.5%, up to 55 °C ±1% Alarms/Diagnostics/Status information
Alarms/Diagnostics/Status Messages
Alarms Yes
Diagnostic function Yes
Diagnostic Display LED
● For output status Yes
Standards, Licenses, Certificates
CE Marking Yes
CSA License Yes
UL License Yes
cULus Yes
FM license yes
RCM (formerly C-TICK) Yes
KC license yes
Shipbuilding license yes
Environmental Requirements
In the open air ● Maximum drop 0.3 m; five in shipping package
Maximum drop 0.3 m; five in shipping package
Ambient temperature during operation
● Minimum -20 °C
● Maximum 60 °C
Level installation, max. -20 °C
Horizontal installation, max. 60 °C ● Vertical installation, max. 60 °C
Vertical installation, max. -20 °C
Vertical installation, max. 50 °C
Ambient temperature during transportation/storage
● Maximum -40 °C
● Max. 70 °C
● Ambient temperature during transportation/storage ● Maximum -40 °C ● Maximum 70 °C ● Pressure according to IEC 60068-2-13
Storage/transportation, max. 660 hPa ● Storage/transportation, max. 660 hPa
Storage/transportation, maximum value 1 080 hPa
Relative Air Humidity
● Operating without condensation at 25 °C, max. 95% ● Storage/transport, max. 1 080 hPa Relative air humidity
Hazardous substance concentration
SO2 at RH < 60%, no condensation Sulfur dioxide: < 0.5 ppm; Hydrogen sulfide: < 0.1 ppm; RH < 60%, no condensation
Mechanical/Materials
Enclosure Material (face)
Plastic Yes
Size
Width 38 mm
Height 62 mm
Depth 21 mm
Weight
Weight, approx. 40 g